Series 1575
Low Water Cut-Off/Pump Controller
For Steam Boilers and Other Level Control Applications
FEATURES
Probe Chamber:
Cast Iron Body
Sight Glass Tappings
Gage Cock Tappings
Stainless Steel Probes
NEMA 4X Electrical Enclosure
250 psi Maximum Working Pressure
Probe Chamber
Electronic Control Unit
McDonnell & Miller
Installation & Maintenance
Instructions
MM-286
Before using this product read and understand instructions.
Save these instructions for future reference.
All work must be performed by qualified personnel trained in the proper application, instal-
lation, and maintenance of plumbing, steam, and electrical equipment and/or systems in
accordance with all applicable codes and ordinances.
To prevent serious bu r n s , the boiler must be cooled to 80˚F (27˚C) and the pressure must be
0 psi (0 bar) before serv i c i n g .
To prevent electrical shock , turn off the electrical power before making electrical connections.
This low water cut-off must be installed in series with all other limit and operating
controls
installed on the boiler. After installation, check for proper operation of all of the limit and
operating controls, before leaving the site.
We recommend that secondary (redundant) low water cut-off controls be installed on all
steam boilers with heat input greater than 400,000 BTU/hour or operating above 15 psi of
steam pressure. At least two controls should be connected in series with the burner control
circuit to provide safety redundancy protection should the boiler experience a low-water
condition. Moreover, at each annual outage, the low water cut-offs should be dismantled,
inspected, cleaned, and c
hecked for proper calibration and performance.
To prevent serious personal injury from steam bl ow dow n , connect a drain pipe to the contro l
opening to avoid exposure to steam discharge.
To prevent a fire, do not use this low water cut-off to switch currents over 16A, 1 Hp at
120 VAC or 8A, 1 Hp at 240 VAC, unless a starter or relay is used in conjunction with it.
Failure to follow this warning could cause property damage, personal injury or
death.
WARNING
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - McDonnell & Miller

Series 1575Low Water Cut-Off/Pump ControllerFor Steam Boilers and Other Level Control ApplicationsFEATURESProbe Chamber:• Cast Iron Body• Sight Glass

Page 2 - Electronic Control Unit

Green LED does not turn on.• There may be no power to the unit. Check wiring connected to ‘H’ and ‘N’ terminals on circuit board.Verify that the contr

Page 3 - SPECIFICATIONS

MAINTENANCESCHEDULE:Blow down control as follows when boiler is inoperation.• Daily if operating pressure is above 15 psi.• Weekly if operating pressu

Page 4 - SPECIFICATIONS (cont.)

8200 N. Austin Ave.Morton Grove, IL 60053tel: 847-966-3700fax: 847-966-9052www.mcdonnellmiller.com©2009 Printed in U.S.A. 2-09 212634

Page 5

2Electronic Control UnitBurner Relay Time DelayThe field-adjustable time delay (DOB) helps to p r event nuisance bu r ner shut-dow n . The number of s

Page 6 - Circuit Board Layout

3SPECIFICATIONSM a x i mum Pressure: 150 psi (10.5 kg/cm2)Burner Delay (DOB): 0 to 60 seconds (Field Adjustabl e )Ambient Te m p : 120˚F Max.N OT E :

Page 7 - Dual Pump Control

4When the water level in the boiler drops below themiddle probe, the circuit is broken which will a c t i vate the pump relay, turning the pump on. W

Page 8 - Interior Lights

Connect wires between C o n t rol Box and P ro b e sas fo l l ow s .P r o b e s C o n t ro lS h o r t e s t / B l u e S h o r t e s t / B l u eM i d d

Page 9 - I N S TA L L ATION COMPLETE

6Circuit Board LayoutSTEP 2 - Electrical Wiring• To prevent electrical shock , turn off the electrical power before making electrical connections.• Th

Page 10 - Troubleshooting

7• Connect wire “ a ” from power supply to t e rminal “ H ” .• Connect wire “ b ” from neutral supply to t e rminal “ N ” .• Connect wire “ c ” from p

Page 11 - MAINTENANCE

8STEP 3 - TestingProcedureTurn on power to the boiler and pump circuits. With the boiler empty,the control will be activated (Green LED On) and the pu

Page 12

Adjusting Burner Delay (DOB)The boiler should begin to fill with wa t e r.N OT E : If water does not start filling the boiler,immediately turn off the

Comments to this Manuals

No comments